LTX300 Lube Control

CODE: HV-LTX300

.

 
 

The LTX300 LubeControl automatic lubrication system is a microcontroller based product that provides extremely accurate & flexible control of grease cycle times with real time monitoring of grease pressure. The module has the added protection of electronic current monitoring to guard against overload & no load (open circuit) situations. Lube cycle times are adjusted via dip switches on the rear of the module. LEDs on the front of the module indicate Power, Lube On, Lube Pressure & Lube Fault. There is an internal Lube Fault buzzer with provision for an external buzzer. A lube cycle can be initiated manually via a button on the front of the module. A key feature of the LTX300 Lube Control is its ability to be configured so that a lube cycle either stops or continues after system grease pressure is met (ie grease pressure switch input activated - Bypass mode enable or disable).

 

Applications

  • Automatic & Manual lube cycle control for mobile plant
  • Lube System Failure Warning Alarm
  • Disperse measured amount of lubricant required

Features

  • Compact design
  • Self Test on Power-Up
  • Electronic Current Monitoring for Overload and No Load Situations
  • Internal circuit protection
  • Fault Warning Alarm Output 
  • Adjustable cycle times via rear mounted dip switches
  • LED Status Indicators
  • Manual Lube Button
  • Inbuilt Alarm Function

 

 

 

 

File name Filesize
LTX300 Lube Control Brochure 429 Kb

Type the characters you see in the picture above.

Voltage...................................................24V

Standby Current.....................................20mA

Operating Current..................................138mA

Timing Accuracy....................................+/-0.1%

Max. Continuous Current.......................5 Amp (Max)

Lube Solenoid open circuit warning.......yes, can be enabled or disabled (Mode 1 shutdown)

Lube Solenoid over current warning......yes, 5 Amp max, always active (Mode 2 shutdown)

Lube Pressure Input...............................Yes, with bypass mode enable or disable operation

Cycle Time Adjust..................................Set by Code Dip Switches (Rear)

On Time Settings...................................30se, 60sec, 90sec, 120sec

Off Time Settings...................................15min, 30min, 45min, 60min

Input / Output Indication.........................Front mounted LEDs

Operation Mode Select..........................Normal only (no test mode)

Lube Fault Indication.............................LED & Buzzer on module, output for remote mounted fault alarm (-ve)

Lube Fault Warning Trigger...................2 consecutive lube cycles without lube pressure input activated

Back to base fault Indication..................No

Electrical Connection.............................1 x Male pin 8 way Deutsch DT connector

Dimensions............................................76mm x 162mm x 55mm (H,W,D Includes mounting bracket)

Weight....................................................328g

Installation..............................................Internal

 