LTX210 Lube Control (Isolated Control Output)

CODE: HV-LTX210

.

 
 

The LTX210 LubeControl Automatic Lubrication System is a microcontroller based product that provides extremely accurate & flexible control of grease cycle times with real time monitoring of grease pressure. The module has the added protection of electronic current monitoring to guard against overload & no load (open circuit) situations. An added feature to the LTX210 is the ability to connect the lube control solenoid output individually with it's own circuit protection. This allows the LTX210 module to still alert the operator should a short circuit fault occur on the lube control solenoid output circuit only.

Applications

  • Automatic lube cycle control for mobile plant
  • Lube System Failure Warning Alarm
  • Dispurse measured amount of lubricant required

Features

  • User selectable timing via rear mounted dip switches
  • Compact design
  • Self Test on Power-Up
  • Electronic Current Monitoring for Overload and No Load Situations
  • Internal circuit protection
  • Fault Warning Output for external back to base monitor system
  • Fault Warning Indicator Output
  • LED Status Indicators
  • Isolated lube control output circuit

 

 

 

 

Type the characters you see in the picture above.

Voltage...................................................24V

Standby Current.....................................20mA

Operating Current..................................138mA

Timing Accuracy....................................+/-0.1%

Max. Continuous Current.......................5 Amp (Max)

Lube Solenoid open circuit warning.......yes, can be enabled or disabled (Mode 1 shutdown)

Lube Solenoid over current warning......yes, 5 Amp max, always active (Mode 2 shutdown)

Lube Pressure Input...............................Yes, (turns lube solenoid off 2 seconds after set pressure reached)

Cycle Time Adjust..................................Set by Code Dip Switches (Rear)

On Time Settings...................................45se, 60sec, 75sec, 90sec

Off Time Settings...................................15min, 20min, 25min, 30min

Input / Output Indication.........................Front mounted LEDs

Mode Select...........................................Normal & Test (via front mounted push button)

Lube Fault Indication..............................LED on module & output for remote mounted indicator (-ve)

Lube Fault Warning Trigger...................2 consecutive lube cycles without lube pressure input activated

Back to base fault Indication..................Yes when connected to a configured modular mining telemetry system

Electrical Connection.............................1 x Male pin 8 way Deutsch DT connector

Dimensions............................................76mm x 162mm x 55mm (H,W,D Includes mounting bracket)

Weight....................................................328g

Installation..............................................Internal